Lead (Pb) is widely used for gamma-ray shielding due to its high attenuation, but its use alone can produce undesirable scatter radiation. To address this challenge, multilayer stacks combining Pb with tungsten (W), bismuth (Bi), copper (Cu), or iron (Fe) were investigated via Monte Carlo simulations using PHITS. Each stack consisted of a Pb layer plus a secondary material layer, and attenuation was evaluated for photon energies from 0.2 to 1.33 MeV using a gas-filled detector and the Beer-Lambert model. Among all configurations, the Pb: W stack exhibited the highest linear attenuation coefficients, ranging from 11.94 cm⁻¹ at 0.2 MeV to 0.57 cm⁻¹ at 1.33 MeV, outperforming pure Pb (11.68–0.46 cm⁻¹), Pb:Bi (9.44–0.40 cm⁻¹), Pb: Cu (5.46–0.36 cm⁻¹), and Pb: Fe (5.38– 0.34 cm⁻¹). Notably, Pb: Bi provided attenuation comparable to pure Pb, offering a potential lower-toxicity alternative. These findings suggest that Pb-based multilayers, particularly Pb: W, can enhance shielding performance while reducing Pb content and mitigating scatter-related issues, representing a viable strategy for improved shielding design.