Abstract

A study on use Of dissolved oxygen probes (DOP) for measurement Of oxygen concentration in warer and wastewater treatment is presented. The principles Of operation, design considerations and selection criteria for Two types of probes, viz. galvanic and polarographic, are discussed Use of polarographic probes in n rhree-phase fluidized bed bioreactor and in laboratory experiments is presented and discussed. The effect of airflow rate and treatment time on dissolved oxygen concentration was found to be significant. It was found that polarographic probes are important equipment in determining the pollution of the industrial effluents. Finally, the use of the DOC probes in treatment process was recommended.

Publisher Name

University of Dar es Salaam