Abstract

The influence of arc discharge duration on turbulent mass burning rate was investigated for turbulent r.m.s vglocities of u '=1.73 m/s and u'=4.5 nfs. Methane air mixtures were used at equivalence ratios ranging from 0.83 to / .25. Flame size was obtained through schiieren photography while the intensity Of CH chemiluminescence emissions was used to measure mass burning rate. A variable spark duration unit was used for ignition sparks and all the experiments were done in a fan stirred bomb. Discharge duration has no effect when the equivalence ratio is I. For higher values longer duration inoeases the burning rate for the early stages of the f!ame up to aflame radius of IO mm. Beyond this the duration does not affect the burning rate. Significant improvement on burning rate is observed for equivalence ratio of 0.83. This decreases as the equtvalence ratio approaches /. For equivalence ratio less than I and forflame radius less than or equal to 5.2 mm a decrease in discharge duration improves mass burning. Geometric flame stretch was found to have significant influence on the burning rate.

Publisher Name

University of Dar es Salaam

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.