Abstract
Substantial improvement of low sensitivity pressure transducers aiming at obtaining a more realistic output signal is discussed. The output signal direct from these transducers has deficiencies of amplitude attenuation and phase lag, thus the measured values are not necessarily the true in- stantaneous values. In order to correct for such shortcomings the unit step response of these transducers is also studied experimentally. A math- ematical model is established based on the experimental results to build up a compensation circuit which is then included in the instrumentation setup to eliminate these deficiencies. The effectiveness of the compensated transducer is demonstrated by meas- uring the pressure profiles close to the air inlet valve of a firing engine. The obtained results are compared with the Ones taken under the same conditions but using more sensitive one (piezo type of transducer) which then acts as a comparator.
Recommended Citation
Mtui, P. (1994). APPLICATION OF IMPROVED PRESSURE TRANSDUCERS FOR PRESSURE MEASUREMENTS. Tanzania Journal of Engineering and Technology (TJET), 18(2), 109-112. https://doi.org/https://doi.org/10.52339/tjet.v18i2.178